{"product_id":"zaptec-pro-me-rueckplatte","title":"Zaptec Pro M\u0026E with backplate – Eichrecht-compliant 22 kW wallbox","description":"\u003cp\u003eThe Zaptec Pro M\u0026amp;E is a 22 kW wallbox that is Eichrecht-compliant in Austria and Germany, with a Type 2 socket, 4G, Wi-Fi and RFID. A type B RCD and circuit breaker are already built into the station, and many stations share one common supply line – saving space in the distribution board and installation costs. It distributes the available power automatically across stations and phases. The backplate that every Zaptec Pro needs is included in all versions.\u003c\/p\u003e\n\u003cp\u003eThe Pro M\u0026amp;E comes in three versions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWallbox with backplate:\u003c\/strong\u003e the basic equipment for every Zaptec Pro – if you already have a Type 2 cable and your connection is sufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV set with Zaptec Sense 65 A:\u003c\/strong\u003e additionally includes Zaptec Sense. Sense measures the building's consumption in the meter cabinet and continuously adjusts the charging power so that the connection is not overloaded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith Zaptec Type 2 charging cable:\u003c\/strong\u003e additionally includes the Zaptec Type 2 charging cable, 5 m, 3-phase, 32 A – ready to go.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging power\u003c\/th\u003e\n\u003ctd\u003eup to 22 kW (3-phase, 32 A), 7.4 kW 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection to the car\u003c\/th\u003e\n\u003ctd\u003eType 2 socket; charging cable only included in the version with charging cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeter\u003c\/th\u003e\n\u003ctd\u003eMID class B, Eichrecht-compliant in Austria and Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003etype B RCD and circuit breaker built into every station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLoad management\u003c\/th\u003e\n\u003ctd\u003eautomatic load and phase balancing; dynamic with Zaptec Sense 65 A – included in the PV set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003e4G, Wi-Fi, powerline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5-year manufacturer warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eA good fit if …\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eyou bill charging electricity to others, even at non-public charging points,\u003c\/li\u003e\n\u003cli\u003ea third party bills the kilowatt hours between two parties,\u003c\/li\u003e\n\u003cli\u003emore parking spaces are to be added and the backplates are mounted in advance,\u003c\/li\u003e\n\u003cli\u003eyour connection is tight – then choose the PV set with Zaptec Sense.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProbably not, if …\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eyou only charge your own car – then a more compact wallbox without Eichrecht, such as the \u003ca href=\"\/en-de\/products\/go-e-core\"\u003ego-e Charger CORE\u003c\/a\u003e, is enough,\u003c\/li\u003e\n\u003cli\u003eyour house connection is above 65 A and you need dynamic load management – then you need Zaptec Sense 150 A or 600 A, just ask us,\u003c\/li\u003e\n\u003cli\u003eyou are ordering for a company, a municipality or an organisation – then our B2B shop \u003ca href=\"https:\/\/shop.ampion.at\" target=\"_blank\" rel=\"noopener\"\u003eshop.ampion.at\u003c\/a\u003e is the right place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat it can do\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegally compliant billing:\u003c\/strong\u003e Eichrecht-compliant metering in Austria and Germany; the data is cryptographically protected and shown at the station.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection on board:\u003c\/strong\u003e A type B RCD and circuit breaker (3 × 40 A type C) are built into every station. A separate type B RCD per charging point in the distribution board is not needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne supply line for many stations:\u003c\/strong\u003e According to Zaptec, up to 30 stations charge simultaneously on one 63 A supply line (TN grid); the system scales up to 100 charging points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo unbalanced load:\u003c\/strong\u003e Dynamic phase balancing automatically distributes single-phase charging cars across all three phases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic charging (PV set):\u003c\/strong\u003e Zaptec Sense adjusts the charging power to the building's current consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug \u0026amp; Charge:\u003c\/strong\u003e ISO 15118-2 via the built-in powerline – plug in and charge, with a compatible vehicle and backend.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare instead of retrofit:\u003c\/strong\u003e The backplate gets the parking space ready; the station is clipped on when needed without touching the electrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways online:\u003c\/strong\u003e 4G, Wi-Fi and powerline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust:\u003c\/strong\u003e IP54, IK10, −30 to +40 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGood to know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAustria (OVE R 37):\u003c\/strong\u003e The Pro M\u0026amp;E also meets the requirements from 15 December 2026.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew installations from 2027:\u003c\/strong\u003e ISO 15118-2 is on board. According to Zaptec, the Pro is ready from 1 January 2027; ISO 15118-20 comes via a free firmware update.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGermany (§14a EnWG):\u003c\/strong\u003e With Zaptec Sense, dimming by the grid operator is possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar surplus:\u003c\/strong\u003e Zaptec currently offers this only in selected countries for small home installations. Austria is not included yet, nor are larger Pro systems. You will therefore mainly use the PV set for dynamic load management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternet for Sense:\u003c\/strong\u003e If Sense loses its connection, the wallbox falls back to the minimum power of 6 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn site:\u003c\/strong\u003e Circuit protected with a maximum of 63 A; cable cross-section 2.5–10 mm². Installation and registration by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhen do I need Eichrecht?\u003c\/h3\u003e\u003cp\u003eWhen kWh of other users are billed or a third party such as a backend or solution provider bills the kWh between two parties – even at non-public charging points.\u003c\/p\u003e\n\u003ch3\u003eDo I need a type B RCD in the distribution board?\u003c\/h3\u003e\u003cp\u003eNo, a type B RCD and circuit breaker are built into every station. Your electrician protects the supply line with a maximum of 63 A.\u003c\/p\u003e\n\u003ch3\u003eDoes it work without the backplate?\u003c\/h3\u003e\u003cp\u003eNo. The backplate is required for every Zaptec Pro and is therefore included in all three versions.\u003c\/p\u003e\n\u003ch3\u003eWhere is Zaptec Sense installed?\u003c\/h3\u003e\u003cp\u003eIn the meter cabinet or distribution board, indoors. Your electrician takes care of it. Sense 65 A is only included in the PV set.\u003c\/p\u003e\n\u003ch3\u003eWhat happens without internet?\u003c\/h3\u003e\u003cp\u003eThe station keeps charging with the offline values last set in the Zaptec portal. According to Zaptec, it should not be operated offline permanently, though.\u003c\/p\u003e\n\u003ch3\u003eCan I mount it on a pedestal?\u003c\/h3\u003e\u003cp\u003eYes, the Zaptec Pro is built for wall and pedestal mounting. The pedestal is not included.\u003c\/p\u003e\n\u003ch3\u003eWhich charging cable do I need?\u003c\/h3\u003e\u003cp\u003eA Type 2 cable rated for 32 A. The version with charging cable already includes the Zaptec Type 2 charging cable (5 m, 32 A).\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer part numbers\u003c\/th\u003e\n\u003ctd\u003e900-00176G (wallbox), ZM000438G (backplate); in the PV set additionally 900-00026 (Sense 65 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAN wallbox\u003c\/th\u003e\n\u003ctd\u003e7090038510605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging power\u003c\/th\u003e\n\u003ctd\u003e22 kW at 32 A 3-phase (TN grid), 12.7 kW 3-phase (IT grid), 7.4 kW 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVehicle connection\u003c\/th\u003e\n\u003ctd\u003eType 2 socket with self-closing cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeter\u003c\/th\u003e\n\u003ctd\u003eMID class B (EN 50470), Eichrecht-compliant in Austria and Germany (PTB-A 50.7), display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003e4G LTE-M, Wi-Fi 2.4 GHz, powerline (HomePlug Green PHY), Bluetooth 5.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eOCPP 1.6J cloud-to-cloud, API, webhooks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAuthorisation\u003c\/th\u003e\n\u003ctd\u003eRFID\/NFC 13.56 MHz, app, Plug \u0026amp; Charge (ISO 15118-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003ebuilt-in type B RCD, circuit breaker 3 × 40 A type C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLoad management\u003c\/th\u003e\n\u003ctd\u003edynamic load and phase balancing; recommended max. 30 stations on 63 A (TN 400 V) or 18 on 63 A (IT 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eISO 15118\u003c\/th\u003e\n\u003ctd\u003eISO 15118-2; ISO 15118-20 from 1 January 2027 via firmware update, according to Zaptec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP54, IK10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−30 to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e392 × 258 × 112 mm, approx. 5 kg including backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZaptec Sense 65 A (PV set only)\u003c\/th\u003e\n\u003ctd\u003e3-phase, inline, max. 65 A; Wi-Fi 2.4 GHz or Ethernet; indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging cable (version with charging cable only)\u003c\/th\u003e\n\u003ctd\u003eZaptec, Type 2 to Type 2, 3-phase, 32 A, 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5-year manufacturer warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eScope of delivery, downloads and accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScope of delivery, wallbox with backplate: 1× Zaptec Pro M\u0026amp;E, 1× Zaptec Pro backplate. Charging cable not included.\u003c\/li\u003e\n\u003cli\u003eScope of delivery, PV set: 1× Zaptec Pro M\u0026amp;E, 1× Zaptec Pro backplate, 1× Zaptec Sense 65 A (3-phase, inline, max. 65 A). Charging cable not included.\u003c\/li\u003e\n\u003cli\u003eScope of delivery, with charging cable: 1× Zaptec Pro M\u0026amp;E, 1× Zaptec Pro backplate, 1× Zaptec Type 2 charging cable (5 m, 3-phase, 32 A).\u003c\/li\u003e\n\u003cli\u003eDownloads: \u003ca href=\"https:\/\/help.zaptec.com\/hc\/article_attachments\/32065364108433\" target=\"_blank\" rel=\"noopener\"\u003eZaptec Pro M\u0026amp;E data sheet\u003c\/a\u003e, \u003ca href=\"https:\/\/help.zaptec.com\/hc\/article_attachments\/26412314597777\" target=\"_blank\" rel=\"noopener\"\u003eZaptec Sense data sheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccessories: \u003ca href=\"\/en-de\/products\/ladekabel-typ-2-32a-22kw-5m-glatt-schwarz-weidmuller\"\u003eWeidmüller Type 2 charging cable\u003c\/a\u003e, 5 m, 22 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Zaptec","offers":[{"title":"Wallbox with backplate","offer_id":64205523059018,"sku":"1230_Set","price":1162.0,"currency_code":"EUR","in_stock":true},{"title":"PV set with Zaptec Sense 65 A","offer_id":64319485378890,"sku":"1254","price":1399.0,"currency_code":"EUR","in_stock":true},{"title":"With Zaptec Type 2 charging cable (5 m)","offer_id":64319485411658,"sku":"1258","price":1339.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/3623\/0218\/files\/Zaptec_ProGreen-Light_View01_R08.webp?v=1793707335","url":"https:\/\/e-leiwand.at\/en-de\/products\/zaptec-pro-me-rueckplatte","provider":"e-leiwand","version":"1.0","type":"link"}